Product categories
- High Temperature Heat Pump
- Energy-Saving ource Multi-Function Heat Pump
- Compressor Placed Indoor Unit Air Source Multi-function Heat Pump
- Compressor Placed Outside Air Source Multi-function Heat Pump
- Integrated air source multifunctional heat pump
- Compressor Placed Indoor Unit Air Source Multi-function Heat Pump(low temperature)
- Compressor Placed Outside Air Source Multi-function Heat Pump(low temperature)
- Ground source multifunctional heat pump
- Evaporative concentration dehumidification heat pump
- heat recovery air source heat pump module
- Ground Source Heat Pump
- Air Source Heater
- Air Source Heat Pump
- cryogenic refrigerating unit
- Evaporative condensing chiller
News center
Contact us
- Add: No.999, Hengshan Road, Kunshan City, Jiangsu Province, China
- Tel: 13616284720
- Fax: {Lankecms_fax}
- Email: 365892459@qq.com
Product Numbers:NSF/DR28-1680
Price:
Product introduction:Adopt 10 °C large temperature difference small flow technology, flow rate is only 50% of the traditional air conditioning, effectively reduce the energy consumption of the transmission system, and improve the energy efficiency of
Large temperature difference and partial second air independent dehumidification air conditioning is a new type of health and energy saving of the central air conditioning, adopting the patent technology .
The air conditioning adopt a part
of the second air independentdehumidification. Then mix with first
air to supply for room , belonging to the low temperature difference of
precision air delivery, healthy and comfortable. In the summer, after the air
through the sensible heat exchanger, part of the second air enter the latent
heat exchanger to dehumidify. Then mixture with first air to supply. Because
it need not send the wind at a machine dew point, the temperature
difference is low, the room temperature is also small , better comfort. In
winter, the air go through duble heat exchanger in turn, energy can be
effectively used, more energy saving.

Chiller use of large temperature difference and
small flow cool water, summer entering water and return water temperature using
17 and 7℃, winter use 35 and 45 ℃, effectively reduce energy consumption of the conveying system , and improve the efficiency of the chiller. The main
features are as follows:
Energy saving:
The use of patented technology of separation thermal and wet , energy full cascade utilization,
effectively improve EER.
The use of large temperature difference between 10
degrees and small flow technology, the flow is only 50% of the traditional
central air-conditioning, effectively reducing the transmission energy
consumption of the pump.
To the whole system, compared with the same type
of traditional central air-conditioning energy saving 30%.
Comfort:
Air conditioning air temperature is
different from the traditional central air conditioning, the use of the air
temperature is higher than the machine dew point temperature, air temperature
difference is small, the room temperature fluctuations
Smaller, control precision, high comfort.
Healthy
The traditional air conditioning uses the machine
dew point to send air, easy to take the wet,to spay. And cause a vent condensation, easy
to breed bacteria, poor health condition.
Because of the traditional air conditioning air
temperature is too low, the temperature fluctuation is large, easy to get air
conditioning disease.
Second independent dehumidification
air-conditioning air temperature is high, it will not cause condensation, good
health conditions, temperature fluctuations small, more conducive to physical
and mental health.
Multi
evaporation temperature
The refrigeration system uses a variety of
evaporation temperature, as far as possible to reduce the irreversible
loss, improve the EER about 20%. .
Overall
investment less
Due to the use of large temperature difference and
low water flow for cooling and heating, reducing the air conditioning pipe
diameter, reducing the pump power, so reducing the investment .
Technical Date:
Air source heat pump main unit

Ground source heat pump main unit


Fan coil and Air handle unit